Views: 0 Author: Site Editor Publish Time: 2026-11-11 Origin: Site
Technical guide · Pandaboard
Direct answer
PVC marble sheet is a PVC foam core with a UV-cured marble face, normally 1220 × 2440 mm at 1.5–5 mm thick (2–3 mm for walls) and about 3–5 kg/m². It is bonded to a flat substrate with construction adhesive in a dot-and-bead pattern; substrate flatness must be within 3 mm over 2 m. Leave 1–2 mm joints and close corners with matching trims. It is not for floors, exteriors or surfaces that stay above 60 °C.
Parameter | Typical range (confirm on order) |
|---|---|
Standard size | 1220×2440 / 1220×2800 mm |
Thickness | 1.5 / 2 / 2.5 / 3 / 5 mm |
Surface weight | about 3–5 kg/m² depending on thickness |
Surface | UV-cured coating, wear and wipe resistant |
Service temperature | ≤60 °C recommended; keep away from hobs and radiators |
Fire performance | Class B1 (per test report) |
Substrate | flatness ≤3 mm over 2 m, moisture ≤8 % |
Interior walls: living, dining and bedrooms
Shop and showroom feature walls
Dry zones of bathrooms and vanity backsplashes
Lift lobbies and corridors
Refurbishment over existing walls (tiles must be keyed first)
Floors (not wear or impact resistant enough)
Outdoor and semi-outdoor use (UV and thermal movement)
Directly above a hob or next to high-temperature equipment
Shower enclosures and permanently wet areas
Walls that must carry heavy loads unless a pattress is added
Substrate flat within 3 mm over 2 m and plumb within 3 mm over 2 m; correct deviations with filler or levelling mortar, never by thickening the adhesive
Substrate dry, moisture content ≤8 %; new plaster cured at least 7 days, with no hollow spots, dust or grease
Existing tiles must be keyed by grinding and primed, and any hollow tile removed — otherwise the new sheet comes away with the tile
Doors, floors and back boxes protected; other wet trades in the room finished
Room at 10 °C or above, RH ≤80 %; cold conditions slow the adhesive and reduce initial grab
Build a 1 m² sample panel first to confirm adhesive compatibility and the colour and grain effect
Table 2-1 Main tools
Tool | Use |
|---|---|
Tape, square, spirit level | Setting out, layout, verticality |
Hook knife or fine-tooth saw | Cutting sheets with a straight edge |
1 m steel rule | Straight edge for cutting and checking |
Drill with paddle | Mixing adhesive |
Cartridge gun, notched trowel | Applying beads and dots |
Rubber mallet and block | Bedding and expelling air |
Masking tape, props | Temporary fixing and joint protection |
Vacuum lifter (large sheets) | Handling and positioning |
2 m straightedge and feeler gauge | Flatness checks |
Quantities are estimated for 100 m² of wall with 1220 × 2440 sheets and 1–2 mm joints, including normal wastage.
Table 2-2 Materials list (reference quantity per 100 m²)
Material | Specification | Reference quantity |
|---|---|---|
PVC marble sheet | 1220×2440, 2–3 mm | 105 m² (about 36 sheets) |
Construction adhesive | MS or polyurethane, 600 ml | 25–30 cartridges (about 0.35 kg/m²) |
Neutral silicone | colour matched, 300 ml | 8–10 cartridges |
Corner and edge trims | matched to the sheet | per perimeter and corners |
Primer | concrete, plaster or tiled substrates | 0.2 kg/m² |
Screw and washer | φ3.5×25 for backer board | 200 sets |
Masking tape | 50 mm wide | about 300 m |
Choosing the adhesiveUse neutral MS or polyurethane construction adhesive only. Acidic silicone attacks the face and gives unreliable bond strength; starch-based adhesives fail as soon as they take up moisture. Use one adhesive throughout a project so differential shrinkage does not create steps between sheets.
Store flat on pallets or bearers, stacks no higher than 1 m with bearers at ≤800 mm; never upright or leaning, which sets a permanent bow in thin sheet
Bring sheets indoors 24 h before installation so they reach room temperature and stop shrinking after bonding
Use one batch and one shade per elevation, stacked with the grain direction marked
Spot-check 5 %: unmarked face, no shade variation, intact protective film, thickness within ±0.2 mm, undamaged corners
Confirm the fitting direction before removing any film, and leave the film on until the wall is complete
For concrete, plaster, plasterboard and calcium silicate substrates that are already flat. No framing, no loss of space and a short programme — but it depends entirely on substrate flatness and correct adhesive coverage.
Figure 3-1 Dot-and-bead layout: continuous bead 20 mm from the edge, interior dots at 300 mm, coverage ≥40 %
Prepare the substrate:Remove dust, grease and release agents; cut out hollow areas and patch with polymer mortar; prime absorbent substrates so the adhesive is not drawn dry.
Set out the layout:Plan to the 1220 × 2440 sheet size and the grain direction with 1–2 mm joints. Keep at least 200 mm beside openings so no sliver is created.
Dry-lay and number:Dry-lay the sheets to check grain matching, shade and the position of switches and sockets, then number the backs in fitting order.
Apply adhesive:Dot-and-bead on the back: a continuous bead 20 mm from the edge (10–15 mm wide) plus interior dots at 300 mm centres at least 40 mm across; coverage ≥40 % and never leave the perimeter bare.
Bed the sheet:Work bottom-up and from external to internal corners. Align to the setting-out lines, press the middle first and then the edges, and tap with a mallet and block to drive air out to the perimeter.
Temporarily brace:Hold the top and middle with masking tape or adjustable props for 24 h so the sheet cannot slide before the adhesive grabs.
Finish the joints:Once cured, clean residual adhesive out of the joint and apply colour-matched neutral silicone or a matching insert; for tight joints, fill flush and strike off.
Trims and openings:Fit matching corner trims, seal the junction with the ceiling, and cut openings for switches and sockets with at least 30 mm from the cut to the sheet edge, finished with a cover frame.
Where the wall is worse than 3 mm over 2 m, or conduit must be buried, build a flat backer first and then bond as Method 1. It adds about 20 mm but hides every defect in the original wall.
Install the frame:C50 steel studs at 400 mm, or 20×30 timber battens at 400 mm, fixed with anchors and levelled against a taut line.
Fix the backer board:9 mm plasterboard or 8 mm calcium silicate board, screws at 200 mm, heads set below the surface, joints staggered and filled.
Level and clean:Backer surface flat within 3 mm over 2 m; grind high spots and fill hollows in thin coats, then dust off.
Bond the sheets:As Method 1 with dot-and-bead; prime absorbent backer board first and increase the adhesive quantity slightly.
Joints and trims:As Method 1, but keep sheet joints at least 200 mm away from backer joints so a crack cannot follow one line through both layers.
Access panels:Provide 300 × 300 access panels where services need attention, using magnetic or hinged frames with matching trim.
For large-format sheets, high walls or where individual sheets must be removable. Aluminum clips on vertical studs engage a groove in the sheet back, leaving a 15–20 mm cavity for services.
Install vertical studs:C50 steel studs at 400 mm, anchored to the wall and levelled to within 2 mm over 2 m.
Groove the sheet back:Cut a groove at least 30 mm from the edge, 3–5 mm deep and slightly wider than the clip; clear the swarf.
Fit the clips:Insert clips into the grooves and spot-fix with neutral adhesive; at least four clips per sheet, six above 2 m height.
Hang and adjust:Hang from the bottom up, adjust with the clip screws, keep joints 2–3 mm and check adjacent sheets within 1 mm with a 2 m straightedge.
Seal and trim:Seal the top and side edges with neutral silicone to keep dust and water out, and close top and bottom with matching trim.
Internal: leave 1–2 mm between the sheets at the corner and fit a matching cove trim, or apply neutral silicone and strike it smooth
External: wrap with a matching angle trim, or mitre the two sheets at 45° and seal — the cut must be perfectly straight or the joint reads as a dark line
Never force a sheet hard into a corner: keep 1 mm behind the trim to absorb movement
Keep joints at 1–2 mm and fill with matching sealant or an insert; uneven joint width is the most visible defect on a marble-faced wall
On elevations longer than 6 m or larger than 30 m², introduce a 2 mm movement joint every 6 m, covered with a matching insert
Leave 2 mm at ceilings, skirtings and door frames and seal with colour-matched neutral silicone
Set out and cut switch, socket and sanitary fixing holes before the sheet goes up, keeping at least 30 mm from the cut to the sheet edge
Point loads above 5 kg must be anchored into the wall or a pattress behind the sheet — never rely on the decorative sheet alone
Seal the cut edge of every opening so moisture cannot reach the core
Install one elevation in one direction, and follow the numbering when the grain is book-matched
Never pair the two most different sheets from a batch; lay them out in daylight before fixing
Under direct downlights, use sheets from a single batch because colour temperature exaggerates any shade difference
Follow the relevant clauses of GB 50210. The values below are normal control limits.
Table 6-1 Permissible deviations and methods of check
Item | Permissible deviation | Method of check |
|---|---|---|
Surface flatness | 2 mm in 2 m | 2 m straightedge and feeler gauge |
Verticality | 2 mm in 2 m | Plumb bob or 2 m straightedge |
Straightness of joints | 2 mm in 5 m | Taut line and steel rule |
Joint width | 1–2 mm, uniform | Steel rule |
Joint step | 0.5 mm | Steel rule and feeler gauge |
Hollow spots | ≤5 % per sheet, ≤3 % overall | Tap test |
Corner squareness | 2 mm | Square |
Appearance | No visible shade difference, scratches or blisters | Daylight and raking light |
Table 7-1 Troubleshooting
Symptom | Usual cause | Remedy and prevention |
|---|---|---|
Hollow spots or sheets coming away | Too little adhesive; dusty substrate; not bedded | Remove, clean and rebond; prime the substrate; keep a continuous perimeter bead |
Joints crack | No gap; adhesive shrinking; substrate movement | Rake out and apply elastic sealant; hold joints at 1–2 mm |
Edges lift | No adhesive at the edge; uneven substrate; load before cure | Add adhesive at the edge and weight for 24 h; flatten the substrate first |
Shade or grain mismatch | Mixed batches; fitted out of sequence | Use one batch in one direction and follow the numbering |
Scratches | Film removed early; tools knocking the face | Keep the film on until completion and turn cut edges to the wall |
Blisters under the face | Damp substrate; adhesive too thick or trapped voids | Dry the substrate; apply even dots and bed thoroughly |
Corners go dark | No sealant, aged sealant or trapped dust | Rake out, clean and re-seal with mould-resistant neutral silicone; fit an angle trim on external corners |
Store flat on pallets or bearers, stacks no higher than 1 m with bearers at ≤800 mm; never upright, leaning or with one end overhanging
Interleave sheets with film so faces cannot rub, and leave the protective film on until installation is finished
Store indoors between −5 and 40 °C, out of sunlight and rain and away from heat sources
Keep away from solvents, oils and sharp objects, and never stack heavy items on the sheets
First in, first out; use within 12 months and check for bowing after long storage
moisture coverdunnage ≥100 mmstack ≤1.2 mlevel basenever store upright
Figure 8-1 Correct stacking: flat, off the floor, no higher than 1 m; upright or leaning storage causes permanent bowing
Load flat, stacks no higher than 1 m, corner protectors fitted and strapped down so nothing shifts or chips in transit
Unload with two people on the edges or with a vacuum lifter; never lift a sheet from the middle, throw it or drag it
Wear goggles and a dust mask when cutting or grooving, and clear cuttings immediately so nobody slips
Keep adhesive and cleaners away from ignition sources and ventilate the work area; no hot work until the adhesive has cured
Work above 2 m from trestles or a mobile scaffold with the harness anchored high; do not overload the platform with sheets
Remove offcuts promptly — thin PVC edges cut hands easily
□Size and thickness match the order (thickness within ±0.2 mm)
□Faces free of scratches, blisters and shade variation
□Protective film intact, corners undamaged
□One grain direction and one batch number
□Packaging intact and clearly marked “store flat”
□Substrate flat within 3 mm over 2 m and plumb
□Substrate dry (≤8 %), with no hollow or dusty areas
□Layout and numbering complete, grain direction confirmed
□Adhesive, corner trims and inserts on site and matched
□Room at 10 °C or above with good ventilation
Can it be bonded over existing tiles?
Yes, provided the tiles are sound, keyed by grinding and primed. If the old tiles are hollow or the glaze is untouched, the adhesive only grips the glaze and the new sheet will come away with the tile.
Do the sheets need joints?
Yes, 1–2 mm. PVC moves with temperature, and tight-butted sheets bow once the room cycles. Fill the joint with colour-matched neutral silicone or a matching insert for a clean line.
Is it suitable for a bathroom?
In dry zones such as a vanity backsplash, yes — provided cut edges and the sheet back are sealed. Inside a shower enclosure it is not recommended; use tiles or a dedicated waterproof panel system.
Can it go behind a kitchen hob?
Keep it at least 200 mm from an open flame and fit a heat shield. Sustained heat dulls and discolours the UV face, so stainless steel or tile is better directly behind the burners.
Which adhesive should I use?
Neutral MS or polyurethane construction adhesive. Acidic silicone attacks the face and gives inconsistent bond strength, and starch or PVA adhesives fail as soon as they take up moisture.
How do I handle a 2440 mm sheet?
Two people on the edges, or a vacuum lifter. Never lift a sheet of this size from the middle: it will crease or crack, and a crease cannot be repaired.
Guangzhou Panda Commercial Development Co., Ltd. · Pandaboard / PEIDA
We manufacture and export gypsum board, mineral fiber and fiberglass ceiling tiles, calcium silicate and magnesium oxide boards, fiber cement board, aluminum ceilings, WPC and SPC wall panels, exterior decking, fencing and handrails, together with the matching grid and framing systems. The methods on this page are compiled from product behaviour and standard trade practice; for any project, follow the approved drawings, local codes and the specification confirmed on your order.
Website: www.pandamanufacturer.com Contact sales: contactus
Send your specification for a quotationView our full product range
Guangzhou Panda Commercial Development Co., Ltd. · Pandaboard / PEIDA
This guide is technical information for specifiers and installers; it does not replace project drawings or local codes.